Configuring The Operational Mode; Configuring The Probe-Timer; Configuring The Echo-Wait-Timer - Alcatel-Lucent OmniSwitch AOS Release 7 Manual

Network configuration guide
Hide thumbs Also See for OmniSwitch AOS Release 7:
Table of Contents

Advertisement

Configuring UDLD

Configuring the Operational Mode

To configure the operational mode, use the
-> udld mode aggressive
For example, to configure the mode for port 4 on slot 2, enter:
-> udld port 2/4 mode aggressive
To configure the mode for multiple ports, specify a range of ports. For example:
-> udld port 2/7-18 mode normal

Configuring the Probe-Timer

To configure the probe-message advertisement timer, use the
-> udld probe-timer 20
For example, to configure the probe-timer for port 3 on slot 6, enter:
-> udld port 6/3 probe-timer 18
To configure the probe-timer for multiple ports, specify a range of ports. For example:
-> udld port 1/8-21 probe-timer 18
Use the no form of this command to reset the timer. For example, the following command resets the timer
for port 4 of slot 6:
-> no udld port 6/4 probe-timer
The following command resets the timer for multiple ports:
-> no udld port 1/8-21 probe-timer

Configuring the Echo-Wait-Timer

To configure the echo-based detection timer, use the
-> udld echo-wait-timer 9
For example, to configure the echo-wait-timer for port 5 on slot 6, enter:
-> udld port 6/5 echo-wait-timer 12
To configure the echo-wait-timer for multiple ports, specify a range of ports. For example:
-> udld port 1/8-21 echo-wait-timer 9
Use the no form of this command to reset the timer. For example, the following command resets the timer
for port 6 of slot 4:
-> no udld port 4/6 echo-wait-timer
The following command resets the timer for multiple ports:
-> no udld port 1/8-21 echo-wait-timer
OmniSwitch AOS Release 7 Network Configuration Guide
udld mode
command as shown:
udld probe-timer
udld echo-wait-timer
March 2011
Configuring UDLD
command as shown:
command as shown:
page 2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch aos 7