Shelf:
1
Unacknowledged Alarms: None
Selection:

Figure 5-31. T1/E1 Quarter Hourly Thresholds Screen - For P/N 1186002L3 Only

Select the desired PM parameter, and press
appears. The user is then able to set the threshold to the desired level and enable/disable an
alarm to be issued once that threshold is exceeded.
Options at the bottom of the menu are used to restore all DS3 and
DS1 defaults.
61186003L1-1D
Slot:
4A
ADTRAN MX2820 System
T1/E1 Statistics - Near End Quarter Hourly Thresholds
1 - CV-L
:
2 - ES-L
:
3 - SES-L
:
4 - LOSS-L
:
5 - CV-P
:
6 - ES-P
:
7 - SES-P
:
8 - UAS-P
:
9 - AISS-P
:
10 - Restore ALL DS3 and DS1 Threshold Defaults
11 - Enable ALL DS3 and DS1 Threshold Alarms
12 - Disable ALL DS3 and DS1 Threshold Alarms
Section 5, User Interface Guide - UIG-520, M13 MUX PM Statistics
TID:
Threshold
Alarm
387
Disabled
25
Disabled
4
Disabled
10
Disabled
387
Disabled
25
Disabled
4
Disabled
2
Disabled
10
Disabled