Table 5-35. STS-1 Alarm Condition Descriptions (Continued)
STS-1 Alarm
Definition
RFI-P
Remote Failure Indi-
cation - Path
TIM-P
Trace Identifier Mis-
match - Path
UEQ-P
Unequipped - Path
5-70
Condition Description
This condition indicates the unit is receiving a line
remote failure indication (RFI-P is declared when the
incoming path remote defect indication [RDI-P, "1" in bit
5 of the G1 path overhead byte for contiguous frames]
lasts for 2.5 ±0.5 seconds.
This condition indicates a received signal label is mis-
matched and does not equal the locally provisioned
expected value.
This condition indicates the path is unequipped and is
not provisioned (Byte C2 of the STS path overhead is set
to zero).
61186003L1-1D