Provision Dsx-1 (T1/E1) Interface; Introduction; Prerequisite Procedures; Dsx-1 (T1/E1) Provisioning Data - ADTRAN MX2820 System Manual

Adtran mx2820 multiplexer: system manual
Hide thumbs Also See for MX2820:
Table of Contents

Advertisement

Provision DSX-1 (T1/E1) Interface

INTRODUCTION

This procedure provides step-by-step instructions to provision the DSX-1 (T1/E1) interface for
the M13 MUX in the MX2820 system.

PREREQUISITE PROCEDURES

Obtain all necessary local instructions before provisioning the DSX-1 (T1/E1) interface. The
parameters need to be set to match the desired application.

DSX-1 (T1/E1) PROVISIONING DATA

Provisioning data includes the following:
• Line State
• Line coding
• Line length
• Loopback detection
• Circuit protection
• Line identification
• Excessive Code Violation (XCV) threshold

T1/E1 Set Multiple

The Set Multiple parameter (value 29) allows setting the same values for a contiguous group of
T1/E1 circuits or setting the same values for all T1/E1 circuits at the same time. To set a
value for all T1/E1 circuits, set First to 1 and Last to 28. Select Apply Settings before leaving
the menu.
To set a value for only some of the T1/E1 circuits, set First and Last to correspond to the lines
desired. Select Apply Settings before leaving the menu.
In the case of 1:1 protection, provisioning the Active MUX module
automatically provisions the Standby MUX module.