To prevent electrical shock, do not install equipment in a wet loca-
tion or during a lightning storm.
Electronic modules can be damaged by static electrical discharge.
Before handling modules, wear an antistatic discharge wrist strap
to prevent damage to electronic components. Place modules in
antistatic packing material when transporting or storing. When
working on modules, always place them on an approved antistatic
mat that is electrically grounded.

PROCEDURE

1. Determine which cable from the network is for transmitting and which is for receiving.
2. Attach the network transmit cable to the MX2820 BNC connector labeled
The fitting is a standard BNC connector. Align the outer ring of the cable connector with
the keys on the shelf connector barrel; press the cable in, and turn approximately one half
turn clockwise to the locking position.
3. Attach the network receive cable to the MX2820 BNC connector labeled
The fitting is a standard BNC connector. Align the outer ring of the cable connector with
the keys on the shelf connector barrel; press the cable in, and turn approximately one half
turn clockwise to the locking position.
4. Route the coaxial cable to the high-speed cross connect or to the appropriate connection
point.
5. If necessary, trim the cable to length and crimp on the appropriate connector for
connecting to the cross connect or other connection point.
6. Repeat
steps 2 - 5

FOLLOW-UP PROCEDURES

Once this procedure is complete, return to the procedure which called out this DLP and
continue with the tasks indicated.
7-68
WARNING
CAUTION
for each MUX module or MUX pair for 1:1 redundant configuration.
.