Set TIRKS Parameters for the SCU

INTRODUCTION

This procedure provides step-by-step instructions to set TIRKS parameters for the System
Controller Unit (SCU). Remote management systems require a specific address and
description for every system they manage. The Target ID (TID) and shelf number must be
registered with the management system before it can find and manage the MX2820 system.
This procedure assigns the codes to the MX2820 shelf for use with the management system.
For multiple MX2820 shelves to operate on a daisy chain con-
nected by the RS-485 bus, all shelves on the daisy chain must
have a unique shelf number to identify the specific shelf. "DLP-712,
Make RS-485 Bus Connections Between Shelves"
STS-1 MUX Installation"
configuration.
The TIRKS system issues the TID and shelf number and should be
provided to the installer as part of the MX2820 installation pack-
age. If not, contact the Central Office (CO) system administrator for
the TID and shelf number assignment. For a CO that does not use
the TIRKS system, values must still be put into the TID and shelf
number locations if the shelf is to be used as a host or client on the
RS-485 bus.

PREREQUISITE PROCEDURES

Obtain all necessary local instructions before proceeding with the MX2820 shelf installation.
The installer or system administrator must be connected and logged on to the MX2820 system
to set the TIRKS parameters for the SCU.
61186003L1-1D
DLP-717
NOTE
provide information about the RS-485
NOTE
and "NTP-004,
7-85