MX2820 System Manual
SYSTEM POWER REQUIREMENTS
Refer to
modules within each List series.
Table 2-2
provides the current draw of each module at –48 VDC. For the M13 and STS-1
modules, this measurement was made with all T1s enabled and configured for maximum line
length. A QRSS data pattern was utilized.
Table 2-2. Current Draw of Each Module at –48 VDC
Part Number
Common Modules
1186003Lx
1186004L1
Multiplexer Modules
1186002Lx
1186005L1
Note: x indicates the list version.
Table 2-3
provides the current draw of each module at ±24 VDC.
Table 2-3. Current Draw of Each Module at ±24 VDC
Part Number
Common Modules
1186003Lx
1186002Lx
Note: x indicates the list version.
2-4
"Section
1,
System Description"
Equipment
SCU
Clock Module
M13 MUX (redundant pair)
STS-1 MUX (redundant pair)
Equipment
SCU
M13 MUX (redundant pair)
NOTE
for voltage requirements of
Maximum Current Draw
–
at
48 VDC
68 mA
52 mA
340 mA
332 mA
Maximum Current Draw
±24
at
VDC
130 mA
720 mA
61186003L1-1D