Table 2-2. Current Draw Of Each Module At -48 Vdc; Table 2-3. Current Draw Of Each Module At ±24 Vdc; System Power Requirements - ADTRAN MX2820 System Manual

Adtran mx2820 multiplexer: system manual
Hide thumbs Also See for MX2820:
Table of Contents

Advertisement

MX2820 System Manual

SYSTEM POWER REQUIREMENTS

Refer to
modules within each List series.
Table 2-2
provides the current draw of each module at –48 VDC. For the M13 and STS-1
modules, this measurement was made with all T1s enabled and configured for maximum line
length. A QRSS data pattern was utilized.
Table 2-2. Current Draw of Each Module at –48 VDC
Part Number
Common Modules
1186003Lx
1186004L1
Multiplexer Modules
1186002Lx
1186005L1
Note: x indicates the list version.
Table 2-3
provides the current draw of each module at ±24 VDC.
Table 2-3. Current Draw of Each Module at ±24 VDC
Part Number
Common Modules
1186003Lx
1186002Lx
Note: x indicates the list version.
2-4
"Section
1,
System Description"
Equipment
SCU
Clock Module
M13 MUX (redundant pair)
STS-1 MUX (redundant pair)
Equipment
SCU
M13 MUX (redundant pair)
NOTE
for voltage requirements of
Maximum Current Draw
at
48 VDC
68 mA
52 mA
340 mA
332 mA
Maximum Current Draw
±24
at
VDC
130 mA
720 mA
61186003L1-1D