MX2820 System Manual
Shelf:
1
Unacknowledged Alarms: None
Current
VT #1
CV-V
ES-V
SES-V
UAS-V
PORT# 1
CV-L
ES-L
SES-L
LOSS-L
AISS-P
Select Interval: (B) to go Back.
Figure 5-45. T1 #1 Near-End Quarter Hourly Statistics (Example)
VT/Port PM Parameter Descriptions (Near End and Far End)
Table 5-36
provides VT/Port PM Near-End and Far-End parameter descriptions.
Table 5-36. VT/Port PM Near-End/Far-End Parameter Descriptions
VT/Port PM
Definition
Parameter
CV-V
Code Violation - VT
ES-V
Errored Seconds -
VT
SES-V
Severely Errored
Second - VT
UAS-V
Unavailable Sec-
onds - VT
5-78
Slot:
4A
ADTRAN MX2820 System
VT/Port Statistics - Near End Quarter Hourly
Total
09:15
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
TID:
09:00
08:45
08:30
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
'?' - System Help Screen
Description
This parameter indicates the number of coding violations
at the VT Layer.
This parameter indicates the number of seconds with
one or more coding violations or an incoming defect
(VAIS, LOP, UNEQ-V) at the VT Layer.
This parameter indicates the number of seconds with x
or more coding violations at the VT Layer, or a second
during which at least one or more incoming defects at
the VT Layer has occurred (Values of x vary dependent
upon the line rate and the Bit Error Rate).
This parameter indicates the time in seconds that the VT
Layer has been unavailable for data delivery.
04/16/04 09:36
HTVLALEXD16
08:15
08:00
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
61186003L1-1D