Table 1-2. Mx2820 M13 Mux Led Descriptions; M13 Mux Front Panel Leds - ADTRAN MX2820 System Manual

Adtran mx2820 multiplexer: system manual
Hide thumbs Also See for MX2820:
Table of Contents

Advertisement

MX2820 System Manual
• Detects and indicates DS3 alarm and loopback conditions
• Local or loop timing modes
• Operates over temperature range of –40°C to +50°C (no fans), –40°C to +65°C (with fans)
• Manual and remote-initiated line and terminal loopback modes
• Reports alarms to SCU
• Supports downloading of FLASH program data from the SCU
• Front panel indication of Active, Alarm, DS3, and DS1 status
• NEBS Level 3, UL60950, GR-1089-CORE compliant
• Hot swappable
• Derives power from redundant VDC supplied to the shelf
• Simplified configuration through the VT100 terminal menu structure

M13 MUX Front Panel LEDs

Table 1-2
provides a description of each LED state for the Active M13 MUX module.
LED
State
Solid Green
ACT
Alternating Green/Amber
Solid Red
Solid Amber
Alternating Red/Amber
Flashing Red
Solid Green
ALM
Solid Red
Flashing Red
Solid Green
DS3 STAT
Solid Red
Flashing Red
One-second Red
Alternating Red/Green
1-10

Table 1-2. MX2820 M13 MUX LED Descriptions

Description
Everything is okay and operating normally
Normal and console open
Self-test failed
Software update in progress
Self-test failed and console open
MUX Module has failed
No critical, major, or minor alarms
Major or minor alarm in progress
Critical alarm in progress
Normal (DS3 okay)
AIS, OOF, RAI, Idle alarms
DS3 LOS or DS3 failure (critical)
A single DS3 line code violation or burst of DS3 line code
violations just occurred
DS3 XCV threshold exceeded
61186003L1-1D

Advertisement

Table of Contents
loading