Figure 5-3. Mx2820 M13 Mux Menu Tree; M13 Mux Menu Tree - ADTRAN MX2820 System Manual

Adtran mx2820 multiplexer: system manual
Hide thumbs Also See for MX2820:
Table of Contents

Advertisement

MX2820 System Manual

M13 MUX MENU TREE

Figure 5-3
shows the menu tree for the MX2820 M13 Multiplexer (MUX) module.
CLEI Code
Part Number
Serial Number
1. Configuration
Code Version
Code Checksum
Boot Version
Boot Checksum
Self Test
2. Provisioning
Shelf:
1
Slot:
Unacknowledged Alarms: CRITICAL MAJOR
DS3 State
State
Alarm
Rx Framing
Remote
3. Status
Multiplexer State
Alarm
Protection
Card Comm.
Slot 1A
Status
Slot 1B
Status
4. Test
5. Performance Monitoring
Note: An asterisk (*) indicates default setting
5-14
1. DS3 Framing
1. Network Interface
2. DS3 Timing
3. DS3 Remote Loopbacks
4. DS3 XCV Threshold
5. IP Forwarding Protocol
6. IP Forwarding MTU
7-13. DS2 Mode (DS2 #1-7)
14. DS3 Equipment Identification
1. T1/E1 State
2. T1/E1 Interfaces
2. T1/E1 Line Coding
3. T1/E1 Line Length
4. T1/E1 Loopback Detection
5. T1/E1 Circuit Protection
6. T1/E1 Line Identification
7. T1/E1 XCV Threshold
1. Card A
2. Card B
3. Service States
3. Facility Service States
1. Perform Manual Switch
2. Minimum Switching Period (sec.) (10*)
4. Protection
3. Maximum Switch Threshold (3*)
5. Save Provisioning
4. Clear Number of Switches
6. Restore Factory Defaults
7. Card Reset
1. Disabled
8. Auto Save
2. Enabled*
9 . Loopback Timeout
10 . Card Pair ID
1A
ADTRAN MX2820 System
TID:
Status
DS2 State
= ALARM
<1-7>
=
NA
NA
NA
NA
= LOS
= M13
T1/E1 State
= Unknown
<1-4>
=
AUTO
AUTO
AUTO
<5-8>
=
AUTO
AUTO
AUTO
<9-12>
=
AUTO
AUTO
AUTO
= None
<13-16> =
AUTO
AUTO
AUTO
= Circuit
<17-20> =
AUTO
AUTO
AUTO
= OK
<21-24> =
AUTO
AUTO
AUTO
<25-28> =
AUTO
AUTO
AUTO
= Active
= Standby
'?' - System Help Screen
1. DS3 Statistics
2. T1/E1 Statistics
3. Clear ALL Statistics

Figure 5-3. MX2820 M13 MUX Menu Tree

1. C-BIT
1. Loop
1. Disabled
2. M13*
2. Local*
2. FEAC/C-BIT*
3. FEAC
4. C-BIT
1. 260 (PREFERRED)*
2. 1500
1. M12 (4xT1)*
2. G.747 (3xE1)
29. Set Multiple
30. Auto Enable Delay
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
(T1/E1 #1-28)
30. Protection Threshold (1-28): 1*
(T1/E1 #1-28)
(T1/E1 #1-28)
1. Disabled*
(T1/E1 #1-28)
2. 1E-3
3. 1E-4
1. IS*
4. 1E-5
2. OOS
5. 1E-6
T1/E1 #1-28
29. DS3
30. Set Multiple
1. Disabled
2. 1 Minute
3. 5 Minutes*
4. 10 Minutes
5. 15 Minutes
6. 30 Minutes
7. 45 Minutes
8. 60 Minutes
04/15/04 16:33
SysName not set
NA
NA
NA
T1/E1 Loopbacks (T1/E1 #1-28)
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
29. DS3 Loopbacks
30-36. DS2 #1-7 Loopbacks
37. Reset ALL Tests
38. Pattern
1. Near End Daily
2. Near End Quarter Hourly
3. Far End Daily
4. Far End Quarter Hourly
5. Near End Daily Thresholds
6. Near End Quarter Hourly Thresholds
7. Near End Daily Thresholds
8. Near End Quarter Hourly Thresholds
9. Clear DS3 Statistics
1. Near End Daily
2. Near End Quarter Hourly
3. Near End Daily Thresholds
4. Near End Quarter Hourly Thresholds
5. Clear T1/E1 Statistics
1. Disabled*
2. 1E-3
3. 1E-4
4. 1E-5
5. 1E-6
1. ADTRAN*
2. PPP
1. 2 seconds*
2. 1 hour
3. 2 hours
4. 12 hours
5. 1 day
6. 2 days
7. 7 days
1. AMI
2. B8ZS/HBD3*
1. Disabled*
2. CSU (T1 Only)
3. NIU (T1 Only)
1. Disabled
2. Enabled*
T1:
1. Data Mode*
2. Tributary
3. Analog Network
4. Digital Line/Net
5. CODEC Line/Net
6. Remote Loopback
7. LS CSU Loopback
8. LS CSU LB w/BERT
9. LS NIU Loopback
10. LS NIU LB w/BERT
11. LS Line BERT
12. HS CSU Loopback
13. HS CSU LB w/BERT
14. HS NIU Loopback
15. HS NIU LB w/BERT
16. HS Line BERT
E1:
1. Data Mode*
2. Tributary
3. Analog Network
4. Digital Line/Net
5. CODEC Line/Net
1. Data Mode*
6. Remote Loopback
7. Line BERT
2. Line Loopback
3. Digital Loopback
4. Remote Loopback
5. Remote ALL T1/E1
1. Data Mode*
2. Network Loopback
1. QRSS*
2. ALL ONES
3. ALL ZEROES
4. 2 in 8 (2:6)
5. 1 in 8 (1:7)
6. 2 ^15-1 INV
61186003L1-1D
1. Disabled
2. Enabled
3. Auto Enable*
T1:
1. 0-133 ft*
2. 133-266 ft
3. 266-399 ft
4. 399-533 ft
5. 533-655 ft
E1:
1. 0-6dB Loss

Advertisement

Table of Contents
loading

Table of Contents