Sts-1 Near-End Daily Thresholds And Alarms; Figure 5-38. Sts-1 Near-End Daily Thresholds - ADTRAN MX2820 System Manual

Adtran mx2820 multiplexer: system manual
Hide thumbs Also See for MX2820:
Table of Contents

Advertisement

STS-1 Near-End Daily Thresholds and Alarms

1. Select
N
E
D
EAR
ND
Figure 5-38
shows an example of the Near-End Daily Thresholds menu screen.
Shelf:
1
Unacknowledged Alarms: None
Selection:
2. Input the number of the desired PM parameter, and press
The menu screen for the selected PM parameter appears. The user is then able to set the
threshold to the desired level and enable/disable an alarm to be issued once that threshold is
exceeded.
Options at the bottom of the menu are used to restore all STS-1 and VT/Port threshold
defaults.
61186003L1-1D
, from the STS-1 Statistics screen.
T
AILY
HRESHOLDS
Slot:
4A
ADTRAN MX2820 System
STS-1 Statistics - Near End Daily Thresholds
1 - CV-L
:
2 - ES-L
:
3 - SES-L
:
4 - UAS-L
:
5 - CV-S
:
6 - ES-S
:
7 - SES-S
:
8 - SEFS-S
:
9 - CV-P
:
10 - ES-P
:
11 - SES-P
:
12 - UAS-P
:
13 - PPJC-P
:
14 - NPJC-P
:
15 - Restore ALL STS-1, VT, and DS1 Threshold Defaults
16 - Enable ALL STS-1, VT, and DS1 Threshold Alarms
17 - Disable ALL STS-1, VT, and DS1 Threshold Alarms

Figure 5-38. STS-1 Near-End Daily Thresholds

Section 5, User Interface Guide - UIG-525, STS-1 MUX PM Statistics
TID:
Threshold
Alarm
382
Disabled
25
Disabled
4
Disabled
10
Disabled
382
Disabled
25
Disabled
10
Disabled
4
Disabled
382
Disabled
25
Disabled
4
Disabled
10
Disabled
5
Disabled
5
Disabled
'?' - System Help Screen
04/16/04 09:02
HTVLALEXD16
.
E
NTER
5-71

Advertisement

Table of Contents
loading

Table of Contents