1 to 9 (1 to 7)
Entering one of these slot identifiers followed by the
ENABLE/DISABLE state for this slot.
Restore Provisions to SCU
This field acts as a global override to disable the restore of all access and MUX module provi-
sions, and is useful in protecting the current SCU settings during SCA restore operations to the
SCU.
Restore Provisions to Modules
This field acts as a global override to disable the restore of all access and MUX module provi-
sions, and is useful in protecting the current access and MUX module settings during SCA
restore operations to the SCU.
If this field disabled, no access or MUX module provisions will be altered during an SCA restore
regardless of the other settings on this screen.
Hot Keys
Pressing the
key will force the restore state of all slots to Enable. Pressing the
E
the restore state of all slots to Disable. Pressing the
61186003L1-1D
Section 5, User Interface Guide - UIG-540, SCU Utilities
key will toggle the SCA restore
E
NTER
key will toggle the restore state of all slots.
T
key will force
D