Options for the T1/E1 XCV Threshold are as follows:
• 1 - Disable. Code violations do not cause the unit to switch.
• 2 - 1E-3. The unit switches if more than one out of every 1,000 bits received on a T1/E1
line contains a code violation.
• 3 - 1E-4. The unit switches if more than one out of every 10,000 bits received on a T1/
E1 line contains a code violation.
• 4 - 1E-5. The unit switches if more than one out of every 100,000 bits received on a T1/
E1 line contains a code violation.
• 5 - 1E-6. The unit switches if more than one out of every 1,000,000 bits received on a
T1/E1 line contains a code violation.
16. Press
as required to return to the MX2820 Main Menu.
E
SC

FOLLOW-UP PROCEDURES

Once this procedure is complete, return to the procedure which called out this DLP and
continue with the tasks indicated.