Step
Check description
17
Replacing the PF main
PWB
18
Replacing the PF main
PWB
19
Replacing the engine PWB The engine PWB is faulty.
J2714: PF conveying sensor 2 stay jam
PF conveying sensor 2 does not turn off after PF feed sensor 2 turns off during paper feed from the large
capacity feeder (cassette 4).
Step
Check description
1
Checking the paper path
2
(When paper skews)
Resetting the paper size
guides
3
(When the paper skew
occurs) Checking the con-
veying guide
Assumed cause
The PF main PWB is
faulty.
The PF main PWB is
faulty.
Assumed cause
The paper is caught with a
piece of paper, etc.
Setting position of the
paper size guides does not
match the paper size.
The paper is caught with
the conveying guide.
7-193
Measures
Replace the PF main PWB.
(Large capacity feeder)
Replace the PF main PWB.
(Side multi feeder)
Replace the engine PWB.
Measures
A piece of paper or the for-
eign objects are adhered on
the conveying path, or if the
parts such as the guide or
the actuator has burrs,
remove them.
Reset the paper size guides
matching the paper size.
Reinstall the conveying
guide. If there are burrs on
the conveying surface of the
conveying guide, remove
them. If not repaired, replace
it.
2WA/2NJ/2RK
Reference
Detaching
and reat-
taching the
PF main
PWB
(Large
capacity
feeder)
Detaching
and reat-
taching the
PF main
PWB (Side
multi
feeder)
Detaching
and Reat-
taching the
engine
PWB
Reference

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Taskalfa 8002iTaskalfa 9002i

Table of Contents