Connec-
Pin
Signal
tor
YC3
5
MPF_LIFT_UP_S
ENS
6
+5V2
7
GND
8
MPF_LIFT_DOW
N_SENS
9
+5V2
10
GND
11
MPF_JAM_SENS
12
+5V2
13
MPF_CL_REM
14
+24V2
15
MPF_LIFT_DR_A
16
MPF_LIFT_DR_B
YC4
1
+24V2
2
ID_SOL_REM
YC5
1
TANK_SET
2
+24V2_IL
3
GND
4
+24V2_IL
5
GND
6
TRANS_MOT_RE
M
7
TRANS_MOT_CL
K
8
TRANS_MOT_RD
Y
9
TRANS_MOT_DI
R
10
TRANS_MOT_BR
K
YC6
1
TRANS_MOT_BR
K
2
TRANS_MOT_DI
R
3
TRANS_MOT_RD
Y
I/O Voltage
I
DC0V/3.3V
O
DC5V
-
-
I
DC0V/3.3V
O
DC5V
-
-
I
DC0V/3.3V
O
DC5V
O
DC0V/24V
O
DC24V
O
DC0V/24V
O
DC0V/24V
O
DC24V
O
DC0V/24V
-
-
-
-
-
-
I
DC24V
-
-
I
DC0V/24V
I
DC0V/
3.3V(pulse)
O
DC0V/3.3V
I
DC0V/3.3V
I
DC0V/3.3V
O
DC24V
-
-
O
DC0V/24V
8-54
Description
MP upper lift sensor: On/Off
DC5V power output to MP upper lift sen-
sor
Ground
MP lower lift sensor: On/Off
DC5V power output to MP lower lift sen-
sor
Ground
MP paper feed sensor: On/Off
DC5V power output to MP paper feed
sensor
MP paper feed clutch: On/Off
DC24V power output to MP paper feed
clutch
MP lift motor: On/Off
MP lift motor: On/Off
DC24V power output to Cleaning solenoid
Cleaning solenoid: On/Off
Not used
Not used
Not used
DC24V power input from Feed PWB
Ground
TRM: On/Off
Transfer motor clock signal
Transfer motor ready signal
Transfer motor drive switching signal
Transfer motor brake signal
DC24V power output to Transfer motor
Ground
Transfer motor: On/Off
2WA/2NJ/2RK-1