Connec-
Pin
tor
YC18
A1
FSR_FAN_ALM
A2
GND
A3
FSR_FAN
A4
EDGE_FAN
A5
+12V5
A6
EDGE_FAN
A7
+12V5
A8
FSR_RLS_DR_C
CW
A9
FSR_RLS_DR_C
W
A10 GND
A11 FSR_SIZE_SENS
A12 +5V2
A13 GND
A14 FSR_RLS_SENS
A15 +5V2
A16 GND
A17 FSR_BLT_PLS
A18 +5V2
A19 NC
B1
IH_RXD
B2
IH_TXD
B3
IH_ERROR
B4
IH_IGBT_CLK_L
OW
B5
IH_IGBT_CLK_HI
B6
+3.3V2
B7
GND
B8
+3.3V2_FUSE2
B9
+3.3V2_THCUT
B10 GND
B11 PRESS_TH
B12 GUIDE_TH1
Signal
I/O
I
DC0V/3.3V
-
-
O
DC0V/24V
O
DC0V/12V
O
DC12V
O
DC0V/12V
O
DC12V
O
DC0V/24V
O
DC0V/24V
-
-
I
DC0V/3.3V
O
DC5V
-
-
I
DC0V/3.3V
O
DC5V
-
-
I
DC0V/
3.3V(pulse)
O
DC5V
-
-
I
DC0V/
3.3V(pulse)
O
DC0V/
3.3V(pulse)
I
DC0V/3.3V
O
DC0V/
3.3V(pulse)
O
DC0V/
3.3V(pulse)
O
DC3.3V
-
-
O
DC3.3V
O
DC3.3V
-
-
I
Analog
I
Analog
Voltage
Rear fuser fan motor alarm signal
Ground
Rear fuser fan motor
Front fuser edge fan motor: On/Off
DC12V power output
Rear fuser edge fan motor: On/Off
DC12V power output
Fuser release motor control signal
Fuser release motor control signal
Ground
Fuser eject sensor: On/Off
DC5V power output
Ground
Fuser release sensor: On/Off
DC5V power output
Ground
Fuser belt sensor
DC5V power output
-
Communication control signal
Communication control signal
IH PWB Error signal
IH_IGBT control signal
IH_IGBT control signal
DC3.3V power output
Ground
DC3.3V power output
DC3.3V power output
Ground
Fuser press thermistor detection voltage
Excessive temperature rise monitor
detection voltage
8-19