Error code
U01021/E01021
Command send retrial times exceeds since significant signal is not received after send-
ing EOR•Q signal. (ECM)
U01022/E01022
Command send retrial times exceeds since significant signal is not received after send-
ing RR signal. (ECM)
U01028/E01028
T5 time-out was detected during ECM transmission (ECM).
U01052/E01052
DCN signal is received after sending RR signal (ECM)
U01080/E01080
PIP signal is received after sending PPS and NULL signals.
U01092/E01092
Communication is stopped since there are impossible combination of symbol speed and
communication speed at V.34 sending.
U01093/E01093
A DCN or other inappropriate signal was received during phase B of transmission.
U01094/E01094
DCS/NSS signal send retrial time is exceeded at phase B during transmission.
U01096/E01096
DCN signal or invalid command is received at phase D during transmission.
U01097/E01097
The preset number of command retransfers was exceeded after transmission of an
RRsignal or no response.
U01100/E01100
Function indicated by DCS signal is not consistent with the one of own machine.
U01101/E01101
Function indicated by NSS signal except communication type is not consistent with the
one of own machine.
U01102/E01102
DTC (NSC) signal is received while own machine has no transmission data.
U01110/E01110
No response is received after sending DIS signal.
U01111/E01111
No response is received after sending DTC (NSC) signal.
U01113/E01113
No response after transmitting an FTT signal.
U01125/E01125
No response after transmitting a CNS signal. (Between the units of our make)
U01129/E01129
No response after transmitting an SPA signal. (Short protocol)
U01141/E01141
DCN signal is received after sending DTC signal.
U01143/E01143
DCN signal is received after sending FTT signal.
U01155/E01155
DCN signal is received after sending SPA signal. (simplified protocol)
U01160/E01160
Maximum transmission time per line is exceeded while receiving message.
U01162/E01162
Reception was aborted due to a modem malfunction during message reception.
U01191/E01191
Communication is stopped with error during image data receipt sequence at V.34.
U01193/E01193
No response, DCN signal or invalid command is received at phase C/D during reception.
U01194/E01194
DCN signal is received at phase B during reception.
U01195/E01195
No message is received at phase C during reception.
U01196/E01196
Error line control overflow and decoding error occurred in messages during reception.
U01400/E01400
An invalid one-touch key was specified during communication.
U01500/E01500
A communication error occurred when calling in V.8 mode.
U01600/E01600
A communication error occurred when called in V.8 mode.
U01700/E01700
A communication error occurred in phase 2 (line probing).
U01720/E01720
The communication error appears at phase 4 (replacing the modem parameter).