Kyocera TASKalfa 7002i Service Manual page 1318

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

C8310: BF side registration motor 2 error
Object: 4000-sheet finisher + Folding unit
BF side registration sensor 2 does not turn on after passing 1s during the initial operation.
Step
Check description
1
Checking the upper BF
side registration guide
2
Checking the upper BF
side registration guide
drive components
3
Checking the connection
4
Replacing BF side regis-
tration motor 2
5
Checking BF side registra-
tion sensor 2
6
Replacing the BF main
PWB
Assumed cause
The upper BF side regis-
tration guide is not assem-
bled properly.
The upper BF side regis-
tration guide drive parts
are not properly attached
or faulty.
The connector is not prop-
erly connected. Or, the
wire is faulty.
BF side registration motor
2 is faulty.
BF side registration sensor
2 is not properly attached
or faulty.
The BF main PWB is
faulty.
7-458
Measures
If the upper BF side registra-
tion guide is not shifted man-
ually back and forth, repair
the part that restricts the
operation.
Reattach the upper BF side
registration guide drive parts.
If not repaired, replace them.
Clean the terminal of the fol-
lowing wire connectors and
reconnect the connectors. If
there is no continuity, replace
the wire. • BF side registra-
tion motor 2 - BF main PWB •
BF side registration sensor 2
- BF main PWB
Execute U240 [Booklet] >
[Width Test(A3)] or [Width
Test(LD)]. If BF side registra-
tion motor 2 does not prop-
erly operate, replace it.
Reattach BF side registration
sensor 2 and execute U241
[Booklet] > [Width Down HP].
If the sensor does not prop-
erly operate, replace it.
Replace the BF main PWB.
2WA/2NJ/2RK
Reference
Wiring dia-
gram
Executing
U240
Executing
U241

Hide quick links: