Kyocera TASKalfa 7002i Service Manual page 1373

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

U01096/E01096
Step
Check description
1
Resending
2
Checking the transmit start
speed
3
Changing the initial value
U01097/E01097
Step
Check description
1
Resending
2
Checking the transmit start
speed
3
Changing the initial value
U01100/E01100
Step
Check description
1
Request for resending
2
Changing the initial value
Assumed cause
DCN signal or invalid com-
mand is received at phase
D during transmission.
Line condition is poor.
(Destination unit)
Line condition is poor.
(Own machine)
Assumed cause
The preset number of com-
mand retransfers was
exceeded after transmis-
sion of an RRsignal or no
response.
Line condition is poor.
(Destination unit)
Line condition is poor.
(Own machine)
Assumed cause
Function indicated by DCS
signal is not consistent
with the one of own
machine.
Line condition is poor.
(Own machine)
7-513
Measures
Resend.
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
Measures
Resend.
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
Measures
Request resending.
Change the reception speed
by executing U630 [RX
Speed].
2WA/2NJ/2RK
Reference
U630 Exe-
cution
U630 Exe-
cution
Reference
U630 Exe-
cution
U630 Exe-
cution
Reference
U630 Exe-
cution