Kyocera TASKalfa 7002i Service Manual page 1369

Hide thumbs Also See for TASKalfa 7002i:
Table of Contents

Advertisement

U01001/E01001
Step
Check description
1
Resending
2
Checking the transmit start
speed
3
Changing the initial value
U01016/E01016
Step
Check description
1
Resending
2
Checking the transmit start
speed
3
Changing the initial value
U01019/E01019
Step
Check description
1
Resending
2
Checking the transmit start
speed
3
Changing the initial value
Assumed cause
Function as indicated by
DIS signal is not consistent
with the one of own
machine.
Line condition is poor.
(Destination unit)
Line condition is poor.
(Own machine)
Assumed cause
T1 timeout occurs since
MBF signal is received but
DIS signal is not after
sending EOM signal.
Line condition is poor.
(Destination unit)
Line condition is poor.
(Own machine)
Assumed cause
Command send retrial
times exceeds since signif-
icant signal is not received
after sending CNC signal.
(between own machines)
Line condition is poor.
(Destination unit)
Line condition is poor.
(Own machine)
7-509
Measures
Resend.
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
Measures
Resend.
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
Measures
Resend.
Execute U630 [TX Speed] to
reduce the transmit start
speed. Then, resend the
data.
Change the default value of
the transmit start speed by
executing U630 [TX Speed].
2WA/2NJ/2RK
Reference
U630 Exe-
cution
U630 Exe-
cution
Reference
U630 Exe-
cution
U630 Exe-
cution
Reference
U630 Exe-
cution
U630 Exe-
cution

Hide quick links: