Step
Check description
3
Replacing the PF main
PWB
C1410: Rotary decurler error
The BR conveying decurler sensor does not turn on after cumulative 3 times of operating 400-steps at
standby. Or, the BR conveying decurler sensor does not turn off after operating 400-steps at standby.
Step
Check description
1
Checking the rotary
decurler
2
Checking the connection
3
Checking the sensor
4
Replacing the BR convey-
ing guide motor
5
Firmware upgrade
6
Replacing the BR main
PWB
7
Replacing the engine PWB The engine PWB is faulty.
Assumed cause
The PF main PWB is
faulty.
Assumed cause
The rotary decurler is not
properly attached.
The connector is not prop-
erly connected. Or, the
wire is faulty.
The BR decurler sensor is
faulty.
The BR conveying guide
motor is faulty.
The firmware is not the lat-
est version.
The BR main PWB is
faulty.
7-370
Measures
Replace the PF main PWB.
(Side multi feeder)
Measures
Check if the rotary decurler or
the drive gears rotate
smoothly and have no exces-
sive load. Then, apply grease
or repair the parts.
Clean the terminal of the fol-
lowing wire connectors and
reconnect the connectors. If
there is no continuity, replace
the wire. • BR decurler sen-
sor - BR main PWB • BR con-
veying guide motor - BR main
PWB • BR main PWB -
Engine PWB
Replace the BR decurler sen-
sor.
Replace the BR conveying
guide motor.
Upgrade the engine firmware
to the latest version
Replace the BR main PWB.
Replace the engine PWB.
2WA/2NJ/2RK
Reference
Detaching
and reat-
taching the
PF main
PWB (Side
multi
feeder)
Reference
Wiring dia-
gram
Firmware
Update
Detaching
and reat-
taching the
engine
PWB