Common rail system
Table of Contents

Advertisement

07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
Classifica-
Signal Name
tion
Exhaust gas
recirculation (EGR)
valve target position
Exhaust gas
recirculation (EGR)
Actua-
valve actual position
tor
Exhaust gas
recirculation (EGR)
position sensor output
Glow (air heater) relay
Differential pressure 1
Differential pressure 1
sensor output voltage
Exhaust gas
temperature 0
Exhaust gas
temperature 0 sensor
output voltage
Exhaust gas
Out-
temperature 1
put
Exhaust gas
temperature 1 sensor
output voltage
Exhaust gas
DPF
temperature 2
data
Exhaust gas
temperature 2 sensor
output voltage
Intake air temperature
built-in MAF
Intake air temperature
built-in MAF sensor
output voltage
Mass air flow for intake
throttle
Intake throttle valve lift
Intake throttle valve lift
output voltage
Engine
During
Unit
Stops
Start-Up
%
Depends on the rotation speed, load and temperature
Approx. the same as the target EGR position
%
(Follow to the target value)
16 to 106 (CAN communication data)
Only during cold start-up (before-and-after): ON
kPa
Input range: –1.7 to 34.5 kPa
V
°C
Representative value:
Approx. 100 °C (212 °F) → Approx. 4.4 V
Representative value:
V
Approx. 250 °C (482 °F) → Approx. 2.3 V
°C
Representative value:
Approx. 100 °C (212 °F) → Approx. 4.4 V
Representative value:
V
Approx. 250 °C (482 °F) → Approx. 2.3 V
°C
Representative value:
Approx. 100 °C (212 °F) → Approx. 4.4 V
Representative value:
V
Approx. 250 °C (482 °F) → Approx. 2.3 V
°C
Representative value:
Approx. 20 °C (68 °F) →Approx. 3.1 V
Representative value:
V
Approx. 80 °C (176 °F) → Approx. 0.9 V
kg/h
12.96 to 698.4 (1.239 to 4.598 V)
100
100
%
(Full open)
(Full open)
Approx.
Approx.
V
0.5 V
0.5 V
1-M18
COMMON RAIL SYSTEM
During
Idling
Accelera-
tion
(Valve lift: 0 to 10 mm)
Output range: 0.5 to 4.5 V
100 to 0
0.5 to 4.375 V
9Y3200007CRM0017US0
During
No-load
Maximum
Speed
KiSC issued 03, 2022 A