Kubota 07-CR-E5 Manual page 146

Common rail system
Table of Contents

Advertisement

07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
Name
Accelerator position sensor error (CAN)
ISO 14229
P-Code
SPN
J1939-73
FMI
SPN Name
proprietary
SAE J1939 Table C1
Accelerator position sensor error (CAN)
DTC Name
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
Limp Home Action
by engine ECU
(system action)
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
Delay time for
recovery
Remark
P2131
523543
2
• Accelerator position sensor signal error
(sensor / harness open circuit, ground
short circuit etc)
• Battery voltage is normal
• Key switch turn ON
• Starter Switch signal (Engine ECU: V12
terminal) is not activated
• Accelerator position sensor error signal
received by CAN
• Transient
• Not applicable
• Insufficient output
• ON
• Diagnostic counter = zero
or Key switch turn OFF
(CAN signal recovers)
• Immediately
Accelerator position sensor correlation
Accel Pedal Sensor 1
Accelerator position sensor correlation
error
• Deviation from designed correlation in
two sensors
• Battery voltage is normal
• Accelerator position sensor 1 is normal
• Accelerator position sensor 2 is normal
• Deviation from designed correlation in
two sensors
• Transient
• Forced Idle
(Accelerator = 0 %)
• Insufficient output
• ON
• Diagnostic counter = zero
or Key switch turn OFF
• 3 sec.
1-S108
COMMON RAIL SYSTEM
error
P2135
91
2
9Y3200007CRS0144US0
KiSC issued 03, 2022 A

Advertisement

Table of Contents
loading

Table of Contents