Kubota 07-CR-E5 Manual page 145

Common rail system
Table of Contents

Advertisement

07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
Name
ISO 14229
P-Code
SPN
J1939-73
FMI
SPN Name
Accelerator Pedal Position 2
SAE J1939 Table C1
DTC Name
Accelerator position sensor 2: Low
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
Limp Home Action
by engine ECU
(system action)
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
Delay time for
recovery
Remark
Accelerator position sensor 2 abnormality
P2127
29
4
• Ground short circuit or open circuit of
sensor / harness
• Battery voltage is normal
• Sensor supply voltage VCC1 is normal
• Voltage of accelerator position sensor 2
is 0.3 V or less
• Transient
• Forced Idle (Accelerator = 0 %)
• Insufficient output
• ON
• Diagnostic counter = zero
or Key switch turn OFF
• 3 sec.
Accelerator Pedal Position 2
Accelerator position sensor 2: High
• Battery short circuit out of sensor /
harness
• Battery voltage is normal
• Sensor supply voltage VCC1 is normal
• Voltage of accelerator position sensor 2
is 4.8 V or more
• Transient
• Forced Idle (Accelerator = 0 %)
• Insufficient output
• ON
• Diagnostic counter = zero
or Key switch turn OFF
• 3 sec.
1-S107
COMMON RAIL SYSTEM
P2128
29
3
9Y3200007CRS0143US0
KiSC issued 03, 2022 A