Name
ISO 14229
P-Code
SPN
J1939-73
FMI
SPN Name
proprietary
SAE J1939 Table
C1
DTC Name
EGR actuator open circuit
• EGR actuator open
Detection item
• Battery voltage is normal
• No DTC of U0077 "CAN1
DTC Set
Preconditions
• EGR control line is
• EGR actuator open error
DTC set parameter
Time to action or
• 2.8 sec. or more
number of error
detection
• Output limitation:
Limp Home Action
by engine ECU
(system action)
• EGR stop
• Insufficient output
Behaviour During
• Worsening exhaust gas
Malfunction
Engine Warning
• ON
Light
Recovery from
• Key switch turn OFF
error
Delay time for
recovery
Remark
P0403
523574
3
circuit
Bus off"
normal
signal received via CAN
Approximately 75 % of
normal condition
performance
EGR actuator abnormality
P0404
523574
4
proprietary
EGR actuator coil short
• EGR actuator coil short
• Battery voltage is normal
• No DTC of U0077 "CAN1
Bus off"
• EGR control line is
normal
• EGR actuator coil short
error signal received via
CAN
• 2.8 sec. or more
• Output limitation:
Approximately 75 % of
normal condition
• EGR stop
• Insufficient output
• Worsening exhaust gas
performance
• ON
• Key switch turn OFF
1-S89
COMMON RAIL SYSTEM
P0409
523572
4
proprietary
EGR position sensor failure
• EGR position sensor
failure
• Battery voltage is normal
• No DTC of U0077 "CAN1
Bus off"
• EGR control line is
normal
• EGR position sensor
error signal received via
CAN
• 2.8 sec. or more
• Output limitation:
Approximately 75 % of
normal condition
• EGR stop
• Insufficient output
• Worsening exhaust gas
performance
• ON
• Key switch turn OFF
9Y3200007CRS0127US0
KiSC issued 03, 2022 A

Advertisement