Kubota 07-CR-E5 Manual page 176

Common rail system
Table of Contents

Advertisement

07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
(1) Terminal Power (+12 V)
(2) Terminal Ground
(3) Terminal AFS
(4) Terminal IATS
(5) Terminal A-GND 10
1. Check the Intake AIr Temperature Sensor Signals
1. Place the key switch in the ON position, and check the "Intake
air temperature" and "Intake air temperature sensor output
voltage" on the diagnosis tool data monitor.
Actual intake air
temperature
20 °C (68 °F)
40 °C (104 °F)
60 °C (140 °F)
80 °C (176 °F)
OK
NG
(a) CAN1 Connector
1-S138
(a) Pin Assignment
(b) Mass Air Flow (MAF) Sensor
(c) Intake Air Temperature
(Built-in MAF)
Service specification
Intake air temperature
20 °C (68 °F)
40 °C (104 °F)
60 °C (140 °F)
80 °C (176 °F)
Clear the DTC and check whether it is output again or not.
OK
Normal.
NG
Replace the engine ECU.
Go to "2. Measure the Resistance Between Terminals".
COMMON RAIL SYSTEM
(d) Engine ECU Connector 1
(Engine Side)
(e) Engine ECU
9Y3200007CRS0174US0
Output voltage
Approx. 3.1 V
Approx. 2.2 V
Approx. 1.4 V
Approx. 0.9 V
9Y3200007CRS0175US0
KiSC issued 03, 2022 A