Kubota 07-CR-E5 Manual page 45

Common rail system
Table of Contents

Advertisement

07-CR-E5,07-CR-TE5,07-CR-TIE5, DM
Heat the accelerator sensor and other electrical components with a hair dryer.
Verify whether or not the voltage value (resistance value) changes.
NOTE
Do not exceed 60 °C (140 °F) (still touchable by hand) when heating.
Do not remove the component case and add heat directly to
electronic parts.
Verify whether or not malfunction symptoms occur under heavy engine loads
(headlights, A/C, wiper, etc. switches ON).
If any commercial electrical products have been installed, remove them and
verify whether or not the malfunction symptoms occur.
If it is thought that the malfunction occurs in rainy or high temperature weather, spray the machine
with water and verify whether or not the malfunction occurs.
NOTE
Do not spray water directly onto the engine. Spray water mist on the entire surface of the
radiator to indirectly change the temperature and humidity of the engine compartment.
Do not spray water directly on electrical parts.
Action
Malfunction symptom
Dead battery
1-S7
COMMON RAIL SYSTEM
Idle speed
abnormal engine
Engine will not
stall sluggish
start
poor
acceleration
9Y3200007CRS0009US0
KiSC issued 03, 2022 A

Advertisement

Table of Contents
loading

Table of Contents