Inspection Procedure For Each System; Air Intake System Inspection Procedure - Kubota 07-CR-E5 Manual

Common rail system
Table of Contents

Advertisement

07-CR-E5,07-CR-TE5,07-CR-TIE5, DM

6. INSPECTION PROCEDURE FOR EACH SYSTEM

[1] AIR INTAKE SYSTEM INSPECTION PROCEDURE

1. Check the Air Cleaner
1. Check the air cleaner for clogging.
• Clean air cleaner element (Primary and Secondary) every 250
hours.
• Replace air cleaner element:
Once yearly or after every sixth cleaning, whichever comes first.
OK
Go to "2. Check the Suction Path".
NG
Clean or replace.
2. Check the Suction Path
1. Check the suction path for leaks. (including EGR valve,
turbocharger, intercooler, etc.)
• Suction path joints.
• Suction pipes, hoses.
NOTE
• A small amount of gas and water bleeds from the valve
chamber gas bleeding hole of the EGR valve. This is
normal.
OK
Normal.
NG
Repair or replace the malfunctioning component.
(1) Hose Clamp
(2) Hose
1-S320
COMMON RAIL SYSTEM
9Y3200007CRS0515US0
(3) Turbocharger
(4) EGR Valve
9Y3200007CRS0516US0
KiSC issued 03, 2022 A

Advertisement

Table of Contents
loading

Table of Contents