Name
ISO 14229
P-Code
SPN
J1939-73
FMI
SPN Name
Aftertreatment 1 Diesel Oxidation Catalyst
SAE J1939 Table C1
Intake Gas Temperature
DTC Name
Exhaust gas temperature sensor 0: Low
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
Limp Home Action
by engine ECU
(system action)
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
Delay time for
recovery
Remark
Exhaust gas temperature sensor (T
P0546
4765
4
• Ground short circuit of sensor / harness
• Battery voltage is normal
• Exhaust gas temperature sensor (T
voltage: 0.08 V or less
• 5 sec. or more
• 0 °C (32 °F) [default value]
• Output limitation: Approximately 75 % of
normal condition
• None
• ON
• Key switch turn OFF
Aftertreatment 1 Diesel Oxidation Catalyst
Intake Gas Temperature
Exhaust gas temperature sensor 0: High
• Open circuit or +B short circuit of sensor
/ harness.
• Battery voltage is normal
• Coolant temperature is 50 °C (122 °F) or
more: continues longer than 5 min. after
engine starting
• 100 °C (212 °F) ≤ T
continues longer than 10 sec. or 100 °C
(212 °F) ≤ T
continues longer than 10 sec.
)
• Exhaust gas temperature sensor (T
0
voltage: 4.92 V or more
• 120 sec. or more
• 0 °C (32 °F) [default value]
• Output limitation: Approximately 75 % of
normal condition
• None
• ON
• Key switch turn OFF
1-S92
COMMON RAIL SYSTEM
) abnormality
0
P0547
4765
3
≤ 800 °C (1472 °F):
1
≤ 800 °C (1472 °F):
2
9Y3200007CRS0130US0