3. ACTIVE TEST AND UTILITY

The 8 items below are used (Security level 2 or higher required).
1
Injector non-injection instruction
2
EGR actuation test
3
Glow relay actuation test
4
Intake throttle valve actuation test
5
NCD check function
6
Supply pump learning (clear the learning value)
7
HMI for PCD
8
HMI for NCD
(Operating conditions → specified tool conditions)
1. The conditions below are required for "Injector non-injection instruction" and "Supply pump learning".
• Machine is stopped
• Neutral switch is ON
From the active test screen
From the utility screen
1-S17
COMMON RAIL SYSTEM
9Y3200007CRS0018US0
9Y3200007CRS0019US0
KiSC issued 03, 2022 A