ECM Main Relay
SAE J1939 Table C1
DTC Name
Main relay is locked in closed position
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
Limp Home Action
by engine ECU
(system action)
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
Delay time for
recovery
Remark
Main relay is locked in closed position
• Failure of main relay
• Key switch is OFF
• Engine stops
• Main relay stays active longer than 1 sec. without command
• 2 times or more
• None
• Dead battery
• OFF
• Diagnostic counter = zero or Key switch turn OFF
• 5.3 sec.