UNI-T MSO/UPO2000 Series Programming Manual page 135

Digital phosphor oscilloscope
Table of Contents

Advertisement

Programming Manual
:BODe:DUT:INPut
:BODe:DUT:INPut
Functional description:
This command is used to set DUT input channel of bode diagram.
Return format:
Query returns {CHANnel1| CHANnel2| CHANnel3| CHANnel4}.
For example:
:BODe:DUT:INPut
Set DUT input channel of bode diagram to channel 1.
:BODe:DUT:INPut
:BODe:DUT:OUTPut
Command format:
:BODe:DUT:OUTPut
:BODe:DUT:OUTPut
Functional description:
This command is used to set DUT output channel of bode diagram.
Return format:
Query returns {CHANnel1| CHANnel2| CHANnel3| CHANnel4}.
For example:
:BODe:DUT:OUTPut
Set DUT output channel of bode diagram to channel 1.
:BODe:DUT:OUTPut
:BODe:GAIN:DISPlay
Command format:
:BODe:GAIN:DISPlay
:BODe:GAIN:DISPlay
Functional description:
This command is used to turn on/off gain display of bode diagram.
Return format:
Query returns gain display status of bode diagram. 0 represents gain display is not open. 1 represents gain
display is opened.
For example:
:BODe:GAIN:DISPlay
:BODe:GAIN:DISPlay
Query returns 1, it represents gain display is opened.
:BODe:GAIN:SCALe
Command format:
:BODe:GAIN:SCALe
:BODe:GAIN:SCALe
Functional description:
Instruments.uni-trend.com
{CHANnel1| CHANnel2| CHANnel3| CHANnel4}
?
CHANnel1
?
{CHANnel1| CHANnel2| CHANnel3| CHANnel4}
?
CHANnel1
?
{{1 | ON} | {0 | OFF}}
?
ON
?
<scale>
?
Query returns CHANnel1.
Query returns CHANnel1.
Turn on gain display of bode diagram.
MSO/UPO2000 Series