UNI-T MSO/UPO2000 Series Programming Manual page 117

Digital phosphor oscilloscope
Table of Contents

Advertisement

Programming Manual
AWG:CHANnel<n>:PULSe:RISe <width>
AWG:CHANnel<n>:PULSe:RISe?
Functional description:
This command is used to set output rising edge pulse width of the specified channel signal pulse wave.
<width> represents pulse width, unit is s.
<n>: channel number, n take value from 1, 2.
Return format:
Query returns output rising edge pulse width of the specified channel signal pulse wave in scietnfic
notation.
For example:
AWG:CHANnel1:PULSe:RISe 0.002
AWG:CHANnel1:PULSe:RISe?
AWG:CHANnel<n>:
Command format:
AWG:CHANnel<n>:PULSe:FALL <width>
AWG:CHANnel<n>:PULSe:FALL?
Functional description:
This command is used to set output falling edge pulse width of the specified channel signal pulse wave.
<width> represents pulse width, unit is s.
<n>: channel number, n take value from 1, 2.
Return format:
Query returns output falling edge pulse width of the specified channel signal pulse wave in scientific
notation.
For example:
AWG:CHANnel1:PULSe:FALL 0.002
Set falling edge pulse width of channel 1 to 2ms.
AWG:CHANnel1:PULSe:FALL?
AWG:CHANnel<n>:MODulate
Command format:
AWG:CHANnel<n>
AWG:CHANnel<n>
Functional description:
This command is used to set modulating type of the specified channel, which is AM
amplitude), FM (modulating frequency)
<n>: channel number, n take value from 1, 2.
Return format:
Query returns modulating type of the specified channel.
For example:
AWG:CHANnel1
AWG:CHANnel1
Instruments.uni-trend.com
:FALL
PULSe
:MODulate
{ AM | FM }
:MODulate
?
:MODulate
AM
:MODulate
?
Set rising edge pulse width of channel 1 to 2ms.
Query returns 2e-3.
Query returns 2e-3.
Set modulating type of channel 1 to AM.
Query returns AM.