UNI-T MSO/UPO2000 Series Programming Manual page 127

Digital phosphor oscilloscope
Table of Contents

Advertisement

Programming Manual
For example:
:LA:DELete GROup1
:LA:DELete?
:LA:GROup<n>:DISPlay
Command format:
:LA:GROup<n>:DISPlay { {1|ON} | {0|OFF} }
:LA:GROup<n>:DISPlay?
Functional description:
This command is used to turn on/off the specified digital channel.
<n>: integer number 1~4, it respectively represents GROup1, GROup2, GROup3 and GROup4.
Return format:
Query returns 1 or 0.
For example:
:LA:GROup1:DISPlay ON
:LA:GROup1:DISPlay?
:LA:GROup<n>:APPend
Command format:
:LA:GROup<n>:APPend <digital0>[, digital1~digital15]
Functional description:
This command is used to add channel for the specified custom group.
<n>: integer number 1~4, it respectively represents GROup1, GROup2, GROup3 and GROup4.
<digital>: it represents {D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|D15}.
For example:
:LA:GROup1:APPend D0,D3
LA Bus
This command is used to set LA bus data and parallel decoding. It can only valid if the oscilloscope has this
instruction.
:LA:BUS<n>:DISPlay
Command format:
:LA:BUS<n>
:LA:BUS<n>
Functional description:
This command is used to turn on/off LA bus status.
<n>: integer data {1|2}, it respectively represents bus 1~2.
Return format:
Instruments.uni-trend.com
Cancel the channel setting of GROup1.
Query returns GROup1.
Turn on GROup1.
Query returns 1.
:DISPlay { {1|ON} | {0|OFF} }
:DISPlay?
Add channel D0 and D3 for GROup1.