:RUN
Command format:
:RUN
Functional description:
This command is used to start the sampling operating of the oscilloscope, if it need to stop, executing:
STOP command.
:STOP
Command format:
:STOP
Functional description:
This command is used to stop the sampling operating of the oscilloscope, if it need to restart, executing:
RUN command.
:AUTO
Command format:
:AUTO
Functional description:
This command is used to automatically set the control parameter of the instrument, the automatic setting
can make the best display effect for the input waveform.
:SYSTem:LOCK
Command format:
:SYSTem:LOCK {{1 | ON} | {0 | OFF}}
:SYSTem:LOCK?
Functional description:
This command is used to lock/unlock full keyboard.
Return format:
Query returns full keyboard locked status, 0 represents locked, 1 represents unlock.
For example:
:SYSTem:LOCK ON/:SYST:LOCK 1
:SYSTem:LOCK OFF/:SYST:LOCK 0
:SYSTem:LOCK?
:SYSTem:ERRor
Command format:
:SYSTem:ERRor
:SYSTem:ERRor?
Functional description:
This command is used to empty error message queue.
Return format:
Instruments.uni-trend.com
Full keyboard locked.
Unlock full keyboard.
Query returns 1, it represents locked.