This command is used to set arbitrary wave play mode switch of the specified channel.
ON represents output with original data; OFF represents it can output by extract point.
<n>: channel number, n take value from 1, 2.
Return format:
Query returns arbitrary wave play mode switch status of the specified channel. 0 represents OFF, 1
represents ON.
For example:
AWG:CHANnel1
Set channel 1 arbitray wave play with original data.
AWG:CHANnel1
WARB Command
This command is used to write arbitrary wave file instruction, which including write configuration of fundamental
arbitrary wave and modulating arbitrary wave.
AWG:WARB<n>:MODulate
Command format:
AWG:WARB<n>:MODulate <arb file>
Functional description:
This command is used to write modulating arbitrary wave, the maximum wave data is 8k points. Send this
instruction first and then send arbitrary wave file data to signal source.
<arb file> represents arbitrary wave data. This instruction is only support .bsv format data.
For example:
AWG:WARB1:MODulate
AWG:WARB<n>:CARRier
Command format:
AWG:WARB<n>:CARRier <arb file>
Functional description:
This command is used to write fundamental arbitrary wave, the maximum wave data is 8k points. Send this
instruction first and then send arbitrary wave file data to signal source.
<arb file> represents arbitrary wave data. This instruction is only support .bsv format data.
For example:
AWG:WARB1:CARRier
LA Command
This command is used to operate digital channel.
Instruments.uni-trend.com
:
ARB:PLAYmode ON
:
ARB:PLAYmode?
Query returns 1.
Write channel 1 modulating arbitrary wave file.
Write channel 1 fundamental arbitrary wave file.