:LA:DIGital<n>:DISPlay
Command format:
:LA:DIGital<n>:DISPlay { {1|ON} | {0|OFF} }
:LA:DIGital<n>:DISPlay?
Functional description:
This command is used to turn on/off the specified digital channel or query the status of the specified digital
channel.
<n>: integer digit 1~16,
it represents {D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|D15}.
It has 16 digital channels.
Return format:
Query returns 1 or 0.
For example:
:LA:DIGital4:DISPlay ON
:LA:DIGital4:DISPlay?
:LA:DIGital
:POSition
<n>
Command format:
:LA:DIGital<n>:POSition <position>
:LA:DIGital<n>:POSition?
Functional description:
This command is used to set or query the display position of the specified digital channel waveform on the
screen. It's only valid when the specified digital channel is opened.
<n>: integer digit 1~16,
it represents {D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|D15}.
<position>: integer
The waveform display mode is small: 0 -31.
The waveform display mode is medium: 0 -15.
The waveform display mode is large: 0 -7.
Return format:
Query returns integer among 0-31, 0-15 or 0-7.
For example:
:LA:DIGital3:POSition 6
:LA:DIGital3:POSition?
:LA:DIGital
:LABel
<n>
Command format:
:LA:DIGital<n>:LABel <label>
:LA:DIGital<n>:LABel?
Functional description:
Instruments.uni-trend.com
Turn on D3.
Query returns 1.
Set the display position of D4 to 6.
Query returns 6.