8.5.8
Blurred image
Cause/Section
Step
Scanner
1
Is the scanner bedewed?
Drum
2
Is the drum bedewed or dirty?
Ozone exhaust 3
Is the ozone exhaust fan operating
properly?
4
Is the ozone filter stained or
damaged?
Main charger
5
Check if the inside wall in the case of
the main charger unit is dirty or there
is any fouling in the case of the main
charger unit.
6
Check if the main charger grid is
corroded, or rusted, or there is any
fouling on the grid.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Fig.8-15
Check item
8 - 303
Measures
Clean it.
Wipe the drum with dry cloth.
Be sure never use alcohol or other
organic solvents because they have
bad effect on the drum.
Check the connection of the
connector.
Replace it.
Clean the inside wall in the case.
Replace the main charger grid.
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING