[CEC5] Incorrect cam position alarm during 2nd transfer
Classification
Copy process related service call
Step
Check Item
2nd transfer contact/release cam
1
unit gear
Actuator in the TRU
2
Sensors in the TRU
3
If any abnormality on a part is
detected and the part is replaced,
the 2nd transfer pressure
reduction is enabled by changing
the value of the setting codes as
follows:
08-4663: 0 to 10: Pressure
reduction disabled1: Pressure
reduction enabled
4
08-4664: 3 to 0Resetting incorrect
cam position error count
Notes:
Change the value of the following codes to disable the pressure reduction:
08-4663: 1 to 0
0: Pressure reduction disabled
1: Pressure reduction enabled
08-4664: 0, 1 or 2 to 3
Resetting incorrect cam position error count
Replace parts
Actuator in the TRU
Sensors in the TRU
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
Printing is finished even though the cam is stopped at an
incorrect position during 2nd transfer pressure reduction.
When this alarm occurs 3 times in total, the 2nd transfer
pressure reduction is disabled (the value of 08-4663 is
automatically turned to "0" from "1"). (The number of
occurrences is stored in 08-4664.)
Result
Check that it is not damaged.
•
Check that it is installed properly.
•
Check that it is not damaged.
•
Check that they are installed
properly.
•
Check that the cam is not
damaged.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
8 - 182
Error item
Measure
Remarks
Next
Step