When any of the stations in the controlling status on the upper row is "2: Sensor abnormality detected"
while "ERROR" is being displayed  Check the setting value of 08-2561  Go to 3.
When any of the controlling statuses on the lower row is "2" while "ERROR" is being displayed  Go to
4.
When "ERROR" is not displayed and the mode returns to the test mode  Go to 6.
When any of service calls CE10, CE20 and CE40 is displayed  Go to 7.
[ 6 ] When "ERROR" is not displayed and the mode returns to the test mode
Print out a test chart (04-231 Y, M, C and K1: Secondary scanning direction - 33-gradation
pattern). Is the printed image normal?
YES  END
|
NO
See "Image quality control related troubleshooting" to resolve the problem.
[ 7 ] CE10, CE20 or CE40 is image quality control abnormality. See "Image quality
control related troubleshooting" to resolve these errors.
8.4.2
Troubleshooting at unpacking
This section describes the procedure needed to interrupt the unpacking procedures in order to inspect
or repair the equipment when trouble occurs during unpacking.
Turn ON the power of the equipment to start the unpacking operation by the software after No. 51of the
unpacking instructions.
This instruction prohibits any operation not described in the unpacking instruction, because the purpose
is to complete the setup of the equipment.
Therefore, if trouble of the equipment occurs during unpacking, it is necessary to forcibly shut down the
unpacking procedure.
When an error code or a service call is displayed after the unpacking procedure is interrupted, clear the
trouble referring to troubleshooting.
When the equipment has been shut down, starting the equipment with the setting code "08-9022"
allows you to know the completed status before the forced termination.
For example, if 6 is displayed for the code 08-9022, this status means that the gamma adjustment has
been completed.
When the error has been cleared, restart the unpacking procedures from the status in which you shut
down the equipment.
Additionally, setting the code 08-9022 to 5 enables you to perform the gamma adjustment again.
Also, setting the code 08-9022 to 99 allows you to release the unpacking operation and to start the
equipment normally.
8.4.3
Drum surface potential sensor control related troubleshooting
when setting up the equipment at unpacking (e-STUDIO6550C/
6570C only)
Troubleshooting V0 sensor controlling status abnormalities when setting up the equipment at
unpacking
[ 1 ] If any abnormality in V0 sensor control is detected, the controlling status and the
"ERROR" message shown below are displayed approx. 30 to 60 seconds after
"Automatic image quality control initialization (05-2742)" is performed. Then
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
8 - 281
8