Download Print this page

Toshiba e-STUDIO5540C Service Manual page 576

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO5540C:

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
Counter
Threshold
C toner
Mode
for nearly
empty
08
Setting
Counter
Threshold
C toner
Mode
for nearly
empty
08
Setting
Counter
Threshold
C toner
Mode
for nearly
empty
08
Setting
Counter
Counter
Sub-hopper toner
Mode
motor driving time
counter
08
Setting
Counter
Counter
Sub-hopper toner
Mode
motor driving time
counter
08
Setting
Counter
Counter
Sub-hopper toner
Mode
motor driving time
counter
08
Setting
Counter
Counter
Sub-hopper toner
Mode
motor driving time
counter
08
Setting
Counter
General
Mode
08
Setting
Counter
Developm
Toner / carrier supply
Mode
ent
motor driving time
counter display
e-STUDIO5540C/6540C/6550C (Ver08)
Sub-
Item
Subitem
Code
code
6454
6454
6454
6466
6466
6466
6466
6467
6469
Default
Acceptable
Details
value
value
4
Threshold to display
830
8 digits
the near empty
message (longer)
5
Threshold to display
900
8 digits
the near empty
message (shorter)
6
Remaining level
935
8 digits
threshold: 0
0
Y
0
8 digits
1
M
0
8 digits
2
C
0
8 digits
3
K
0
8 digits
Number of output
2
0-7
pages available at
toner cartridge
replacement (during
cover open)
0
Y
0
8 digits
169
RAM
Contents
M
Sets the timing for when the toner near empty display
appears.
The period of time (number of counts) from the
appearance of the near empty display to actually
running out of toner is longer (larger) than that of
"center".
The larger the value, the later the display appears.
[Unit: 1 count = 500 ms]
M
Sets the timing for when the toner near empty display
appears.
The period of time (number of counts) from the
appearance of the near empty display to actually
running out of toner is shorter (smaller) than that of
"center".
The larger the value, the later the display appears.
[Unit: 1 count = 500 ms]
M
Sets the timing for when the toner remaining level is 0%
appears.
[Unit: 1 count = 500 ms]
M
Counts the drive count of each sub-hopper toner motor.
M
Counts the drive count of each sub-hopper toner motor.
M
Counts the drive count of each sub-hopper toner motor.
M
Counts the drive count of each sub-hopper toner motor.
SYS 0: 01: 1002: 2003: 5004: 10005: 15006: 20007: No
limitation(99999999)[Unit. page]
M
Counts the driving time of each sub-hopper toner motor.
This value is the accumulation since the start of use or
the last replacement of developer material.
Proce
Servic
dure
e UI
4
Yes
4
Yes
4
4
4
4
4
1
4

Advertisement