Download Print this page

Toshiba e-STUDIO5540C Service Manual page 258

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO5540C:

Advertisement

[5030] TOSHIBA Remote monitoring system error (HTTP communication error)
Classification
Communication error with external
application
Check item
Setting
[50FF] TOSHIBA Remote monitoring system error (eBR2 internal error)
Classification
MFP internal error
Check item
Setting
[5110] Toner cartridge detection error
Classification
TopAccess related error
Check item
Setting
[5BD0] Power failure during restoration
Classification
TopAccess related error
Check item
Setting
Replace parts
[5C10] FAX Unit attachment error
Classification
TopAccess related error
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
An error in the HTTP communication
Check the URL for communication.
Check that the valid IP address is assigned to connect to
the server.
A fatal error occurred in the MFP
Restart the MFP, and then try again.
Check if the toner cartridge is installed properly.
Check if the toner cartridge detection sensor operates
properly.
Check if the power cable is connected properly and is
inserted securely.
Check if the power voltage is unstable.
Reattempt the restoration of the database (Address Book,
templates, F-code (Mailbox) or user information).
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
8 - 257
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures
Remarks
Error item
ERROR CODE and TROUBLESHOOTING
8

Advertisement

loading