8.3.17
RADF related service call
[C730] EEPROM abnormality
Classification
Optional communication related
service call
Check item
RADF board
Replace parts
RADF board
[C880] RADF original feed motor abnormality
Classification
Optional communication related
service call
Check item
RADF board
RADF original feed motor (MR1)
Replace parts
RADF original feed motor
RADF board
[C890] RADF read motor abnormality
Classification
Optional communication related
service call
Check item
RADF board
RADF read motor (MR2)
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Data abnormality occurs during the EEPROM writing of the
RADF is performed.
•
Connector check
•
Harness check
•
Board check IC12)
Replace the RADF board, and then perform the automatic
adjustment for the original reading start sensor (05-3210).
An error signal has been detected when the motor is rotating.
•
Connector check (CN76)
•
Harness check
•
Board check
•
Motor check
(Perform the output check: 03-281)
•
Connector check
•
Harness check
Replace the RADF board, and then perform the automatic
adjustment for the original reading start sensor (05-3210).
An error signal has been detected when the motor is rotating.
•
Connector check (CN76)
•
Harness check
•
Board check
•
Motor check
(Perform the output check: 03-283)
•
Connector check
•
Harness check
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
8 - 129
Error item
Measures
Remarks
Error item
Measures
Remarks
Error item
Measures
ERROR CODE and TROUBLESHOOTING
8