Toshiba e-STUDIO5540C Service Manual page 724

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO5540C:

Advertisement

Sub
05/08
Mode
Element
element
05
Adjustmen
Process
Transfer
t mode
05
Adjustmen
Process
Charger
t mode
05
Adjustmen
Process
Charger
t mode
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
controlling status
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
controlling status
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
controlling status
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
controlling status
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
output
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
output
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
output
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
output
05
Adjustmen
Process
Image
Drum surface
t mode
control
potential sensor
output
e-STUDIO5560C/6560C/6570C (Ver08)
Sub-
Item
Subitem
Code
code
2762
2763
2764
2780
2780
2780
2780
2782
2782
2782
2782
2782
Default
Acceptable
Details
value
value
Temperature/humidity
50
0-100
sensor humidity
display
Drum thermistor
23
0-100
temperature display
(K)
Drum thermistor
23
0-100
temperature display
(Y)
0
Sensor shutter-Y
0
0-2
1
Sensor shutter-M
0
0-2
2
Sensor shutter-C
0
0-2
3
Sensor shutter-K
0
0-2
0
Y (low bias)
292
0-999
1
M (low bias)
292
0-999
2
C (low bias)
292
0-999
3
K (low bias)
292
0-999
5
Y (high bias)
886
0-999
5
RAM
Contents
M
Displays the preset humidity at the beginning of
warming-up.
M
(Unit: ºC)
M
(Unit: ºC)
M
Displays the controlling status of the drum surface
potential sensor with a digit as follows:
0: Normally finished1: Control paused2: Sensor
abnormality
M
Displays the controlling status of the drum surface
potential sensor with a digit as follows:
0: Normally finished1: Control paused2: Sensor
abnormality
M
Displays the controlling status of the drum surface
potential sensor with a digit as follows:
0: Normally finished1: Control paused2: Sensor
abnormality
M
Displays the controlling status of the drum surface
potential sensor with a digit as follows:
0: Normally finished1: Control paused2: Sensor
abnormality
M
Outputs the detection value of the drum surface
potential sensor when the drum surface potential sensor
shutter is opened.
M
Outputs the detection value of the drum surface
potential sensor when the drum surface potential sensor
shutter is opened.
M
Outputs the detection value of the drum surface
potential sensor when the drum surface potential sensor
shutter is opened.
M
Outputs the detection value of the drum surface
potential sensor when the drum surface potential sensor
shutter is opened.
M
Outputs the detection value of the drum surface
potential sensor when the drum surface potential sensor
shutter is opened.
Proce
Servic
dure
e UI
2
2
2
10
10
10
10
10
10
10
10
10