Step
Check item
21
Compare them with the
statues of [G] and [H]
displayed in step 14.
22
23
Compare it with the statue of
[G] displayed in step 15.
24
25
26
27
28
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
Result
Both [G] and [H] are changed - The image
position aligning sensors on both sides are
operating normally.
[G] remains same - The image position
aligning sensor on the rear side is not
operating normally.
[H] remains same - The image position
aligning sensors on the front side is not
operating normally.
Both [G] and [H] remains same - The image
position aligning sensors on both sides are
not operating normally.
Check how item [G] is displayed while [9] is
pressed.
[G] is changed - The image position aligning
sensor on the center side is operating
normally.
[G] remains same - The image position
aligning sensor on the center side is not
operating normally.
Press the [CLEAR] button.
Key in "167", then press the [START] button.
(03-167: Image position aligning sensor / LED
OFF)
Key in "168", then press the [START] button.
(03-168: Sensor shutter closed)
Turn the power OFF.
If the image position aligning sensors on all
sides are operating normally, proceed to step
(30). In other cases, proceed to step (29).