Installation
Four actor ports for connection to a door opener and the intercom of door-
station equipment. These are designed as pressure terminals (actor1 and
actor3 to activate door openers, actor2 and actor4 to activate doorstation
equipment)
Four sensor ports for connection to the bell keys of doorstation equipment,
designed as pressure terminals (sensor 1 to sensor 4)
One slot to incorporate a V.24 add-on card. The following port can be used with
the V.24 add-on card:
one COM port to connect to a PC to configure and transmit connection data,
designed as an RJ45 jack
Two PCM ports for the connection of up to three systems, designed as an RJ45
socket (PCM)
Two ports to the LAN (100BaseT), designed as RJ45 jacks
One CompactFlash socket to incorporate a type I or type II CompactFlash
memory card. These cards are necessary to operate the OpenVoice and Open-
Attendant programme packages. Only use high speed memory cards which
are recommended by Aastra. Other memory cards or "Microdrive" type
memory cards may not be able to maintain the required access speed.
Tip:
One port jack to connect the plug-in power supply. Only use the original
OpenCom 150 plug-in power supply provided in the supply scope.
40
For the stored voice announcements and a recording time of
one hour a memory card with 32 Mbyte is required.