Unit system
Description
● Measurement unit can be selected from metric or inch system.
● Metric system (factory set)
Length ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ mm
Flow velocity ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ m/s
Volume flow rate unit ꞏꞏꞏꞏꞏꞏꞏ L/s, L/min, L/h, L/d, kL/d, ML/d, m
Flow rate total unit ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ mL, L, m
Mass flow rate unit ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ g/s, g/min, g/h, g/d, kg/s, kg/min, kg/h, kg/d, t/s, t/min, t/h, t/d
Mass total unitꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ g, kg, t
Viscosity coefficient ꞏꞏꞏꞏꞏꞏꞏꞏꞏ E
Pressure ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ MPa (G), bar (G) (G: gauge pressure)
Temperature unit ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ °C, K, °F
Density ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ kg/m
<Note> Set the total mode to "STOP" before setting this parameter. (See Section 4.8.2.)
For actual keying, refer to the typical operation indicated below. Set the protection to OFF beforehand. (See Section 4.4.1.)
Operation
Change the unit system from inch system to metric system.
(example)
Key operation
Measurement mode display before changes
Press the
▼
ENT
Press the
▼
Press the
ENT
▼
Press the
▼
Press the
ENT
▼
Press the
ESC
measurement mode.
4.7. Setting of unit
BBL/d, kBBL/d, MBBL/d
3
, km
3
, Mm
3
, mBBL, BBL, kBBL
-6
m
2
/s
3
Description
key for 3 times to display "MEASURE SETUP".
ENT
key once to display "SYSTEM UNIT".
key once to blink the cursor.
ENT
key once to display "METRIC".
key once to register.
ENT
――― METRIC has been registered. ―――
key once and
key twice to return to the
ESC
3
/s, m
3
/min, m
3
/h, m
3
/d, km
-32-
3
/d, Mm
3
/d, BBL/s, BBL/min, BBL/h,
Display
0.000
ft/s
0.000
ft3/h
MEASURE SETUP
SYSTEM UNIT
SYSTEM UNIT
SYSTEM UNIT
METRIC
SYSTEM UNIT
COMPLETE
↓
SYSTEM UNIT
METRIC
0.000
m/s
0.000
m3/h
INCH
INCH