Setting unit
37
OUTPUT LIMIT LOW
38
OUTPUT LIMIT HIGH
39
RATE LIMIT
40
RATE LIMIT TIMER
41
TOTAL MODE
42
VolumeTOTAL RATE
43
V:TOTAL PRESET
44
MASS TOTAL RATE
45
M:TOTAL PRESET
46
PULSE WIDTH
47
BURNOUT (TOTAL)
48
BURNOUT TIMER
49
DO1 OUTPUT TYPE
50
DO1 OUTPUT OPERATION
51
DO2 OUTPUT TYPE
52
DO2 OUTPUT OPERATION
53
Zero calibration
54
Span calibration
55
AI RANGE KIND
56
AI BASE SCALE
57
AI FULL SCALE
58
Communication mode
59
COMMUNICATION BAUD RATE
60
COMMUNICATION PARITY
61
COMMUNICATION STOP BIT
62
COMMUNICATION STATION NO.
63
LIGHTS-OUT TIME
64
MAINTENANCE
Setting range
Initial value
-20 to 0%
-20%
100 to 120%
120%
0,±0.3 to ±50m/s in
40.000 m
terms of flow velocity
0 to 900sec
1 0 sec
No. of menu: 3
STOP
0.000000 to 99999999
0 m3
0.000000 to 99999999
0 m3
0.000000 to 99999999
0 m3
0.000000 to 99999999
0 kg
No. of menu: 7
50.0 msec
No. of menu: 2
Hold
10 to 900sec
10 sec
No. of output content
Not used
menu: 16
No. of alarm menu: 3
VOL. Flow switch
range
0 to 50m/s in terms of
flow velocity
Mass Flow switch
range
0.000000 to 99999999
Vol.Total switch range
0.0
to 99999999
Mass Total switch
range 0.000000 to
99999999
No. of menu: 2
Active ON
No. of output content
Not used
menu: 16
No. of alarm menu: 3
VOL. Flow switch
range
0 to 50m/s in terms of
flow velocity
Mass Flow switch
range
0.000000 to 99999999
Vol.Total switch range
1.0 to 99999999
Mass
Total
switch
range
0.000000
to
99999999
No. of menu: 2
Active ON
-5 to 5m/s in terms of
0.000m
flow velocity
-200.00 to 200.00%
100.00%
No. of menu: 3
NOT USED
±99999999
0
±99999999
0
No. of menu: 1
RS-485
No. of menu: 3
38400 bps
No. of menu: 3
Odd
No. of menu: 2
1 bit
1 to 31
1
0 to 99min
0
No. of menu: 2
STOP
-26-
Setting range Setting value
[%]
[%]
/h
This is the initial value of 50 A pipe size.
3
Change the setting when using a pipe size above
50 A.
65 A: 65 m
/h, 80 A: 92 m
3
[sec]
START, STOP, TOTAL RESET
[5.UNIT]
[5.UNIT]
[7.UNIT]
[7.UNIT]
5.0 msec, 10.0 msec, 50.0 msec, 100.0 msec,
200.0 msec, 500.0 msec, 1000.0 msec
Not used, Hold
[sec]
 +Vol.TOTAL PULSE
 -Vol.TOTAL PULSE
 +MassTOTAL PULSE
 -MassTOTAL PULSE
 FULL SCALE 2
 ALARM [ALL, HARDWARE FAULT, PROCESS
ERROR]
 Vol.FLOW SWITCH
 Vol.FLOW SW HIGH [
 Vol.FLOW SW LOW [
 MassFLOW SWITCH
 MassFLOW SW HIGH [
 MassFLOW SW LOW [
 Vol.TOTAL SWITCH [
 MassTOTAL SWITCH [
 AO RANGE OVER
 PULSE RANGE OVER
 -: FLOW DIRECTION
 INPUT ALARM
 MAINTENANCE
Active ON, Active OFF
 +Vol.TOTAL PULSE
 -Vol.TOTAL PULSE
 +MassTOTAL PULSE
 -MassTOTAL PULSE
 FULL SCALE 2
 ALARM [ALL, HARDWARE FAULT, PROCESS
ERROR]
 Vol.FLOW SWITCH
 Vol.FLOW SW HIGH [
 Vol.FLOW SW LOW [
 MassFLOW SWITCH
 MassFLOW SW HIGH [
 MassFLOW SW LOW [
 Vol.TOTAL SWITCH [
 MassTOTAL SWITCH [
 AO RANGE OVER
 PULSE RANGE OVER
 -: FLOW DIRECTION
 INPUT ALARM
 MAINTENANCE
Active ON, Active OFF
/h
[7.UNIT]
3
%
NOT USED, PRESSURE, TEMPERATURE
[8. or 9.UNIT]
[8. or 9.UNIT]
RS-485
9600 bps, 19200 bps, 38400 bps
None, Odd, Even
1 bit, 2 bits
[min]
STOP, START
/h, 100 A: 156 m
/h
3
3
* Note1
[4.UNIT]]
[4.UNIT]]
[6.UNIT]]
[6.UNIT]]
[5.UNIT]]
[7.UNIT]]
* Note1
[4.UNIT]]
[4.UNIT]]
[6.UNIT]]
[6.UNIT]]
[5.UNIT]]
[7.UNIT]]