10.13 o: Keypad-Related Settings

o2: Keypad Operation

No.
Name
(Hex.)
o2-02
STOP Key Function
Selection
(0506)
o2-03
User Parameter Default
Value
(0507)
o2-04
Drive Model (KVA)
Selection
(0508)
o2-05
Home Mode Freq Ref
Entry Mode
(0509)
o2-06
Keypad Disconnect
Detection
(050A)
o2-07
Keypad RUN Direction
@ Power-up
(0527)
o2-23
External 24V Powerloss
Detection
(11F8)
RUN
o2-24
LED Light Function
Selection
(11FE)
o2-26
Alarm Display at Ext.
24V Power
(1563)
o2-27
bCE Detection Selection
(1565)
526
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to use
on the keypad to stop the drive when the Run
command source for the drive is REMOTE (external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to keep the settings of changed parameters as user parameter defaults
to use during initialization.
0 : No change
1 : Set defaults
2 : Clear all
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Drive Model code. Set this parameter after replacing the control board.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that makes it necessary to push
frequency reference value while in Drive Mode.
0 : ENTER Key Required
1 : Immediate / MOP-style
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that stops the drive if you disconnect the keypad connection cable
from the drive or if you damage the cable while the keypad is the Run command source.
0 : Disable
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation when the drive is energized and the keypad is the
Run command source.
0 : Forward
1 : Reverse
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to give a warning if the backup external 24 V power supply turns off
when the main circuit power supply is in operation.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to show the LED status rings and keypad LED lamps.
0 : Enable Status Ring & Keypad LED
1 : LED Status Ring Disable
2 : Keypad LED Light Disable
V/f
CL-V/f
OLV
CLV
AOLV
When you connect a backup external 24 V power supply, this parameter sets the
function to trigger an alarm when the main circuit power supply voltage decreases.
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive operation if the Bluetooth device is disconnected when you operate the drive
in Bluetooth Mode.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
to use the keypad to change the
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Default
Ref.
(Setting Range)
1
788
(0, 1)
0
788
(0 - 2)
Determined by the drive
789
(-)
0
789
(0, 1)
0
789
(0, 1)
0
789
(0, 1)
0
790
(0, 1)
0
790
(0 - 2)
0
790
(0, 1)
3
790
(0 - 4)

Advertisement