Chapter 3 — Developing and Using RFID Applications
78
Read Tries
Sets the maximum number of times the read algorithm is
executed before a response is returned to a Read command.
In practice, this is the number of times an identified tag will be
read until the Read is successful. Valid range is 1 (default) to 254.
This setting is equivalent to the RDTRIES BRI attribute.
Write Tries
Sets the maximum number of times the write algorithm is
executed before a response is returned to a Write command.
In practice, this is the number of times an identified tag will be
written to until the Write is successful. Valid range is 1 (default)
to 254.
This setting is equivalent to the WRTRIES BRI attribute.
Init Tries
Sets the maximum number of times the reader attempts to
initialize a tag. Valid range is 1 (default) to 254.
This setting is equivalent to the INITTRIES BRI attribute.
Lock Tries
Sets the maximum number of times the lock algorithm is
executed before a response is returned to a Lock command. Valid
range is 1 (default) to 254.
This setting is equivalent to the LOCKTRIES BRI attribute.
Select Tries
(Not supported by EPCglobal Class 1 Gen 2 tags) Sets the
number of times a group select is attempted. A group select is the
command that starts the identity process. Valid range is 1
(default) to 254.
This setting is equivalent to the SELTRIES BRI attribute.
Unselect Tries
(Not supported by EPCglobal Class 1 Gen 2 tags) Sets the
number of times a group unselect is attempted. Valid range is 1
(default) to 254.
IF5 Fixed Reader User's Manual